Product information "MXZ Outdoor unit R32".
Technical changes and errors excepted ! Subject to prior sale !
The leakage of refrigerants contributes to climate change. Refrigerants with a lower global warming potential (GWP) contribute less to global warming in the event of a leak than those with a higher global warming potential (GWP). A leak of 1 kg of this refrigerant would therefore have a greater impact on global warming than 1 kg of CO2, based on a hundred years, according to the GWP value of the refrigerant. Do not work on the refrigerant circuit or disassemble the unit - always consult qualified personel.
Model: | MITSUBISHI / MXZ-5F102VF |
Technical data : | |
CoolingPower Min/Standard/Max (kW): | 3,9 / 10,2 / 11,0 |
S.E.E.R: | 6,6 |
Heating capacity Min/Standard/Max (kW): | 4,1 / 10,5 / 14,0 |
S.C.O.P: | 4,2 |
Power consumption cooling / Heizen (kW): | 3,91 / 2,90 |
Energieeffizienzklasse cooling / Heizen : | A++ / A+ |
Einsatzbereich (°C): | −10~+46 / −15~+24 |
Designation outdoor units | |
Air volume flow (m3 / h): | 3396 |
Sound pressure level cooling /Heizen (dB(A)): | 53 / 55 |
Dimensions W / D / H (mm): | 950 / 330 / 796 |
Weight (kg): | 63 |
Connectable indoor unite (Anzahl): | 2 – 5 |
Coolingtechnische Angaben : | |
Gesamtleitungslänge (m) | 80 / 25 |
Max. Height difference (m) | 15 / 10 |
Cooling agent type GWP/CO2 -Equivalent (t)/CO2 -Equivalent max. (t) | R32 2088 / 6,25 / 9,6 |
Cooling agent prefill for (m) | 0 |
Cooling agent refill quantity (g /m) | 20 |
Cooling connections Ø (mm) fl. s. | 5 x 6 1 x 12 / 4 x 10 |
Electrical data | |
Power supply (V, Phase, Hz) | 220 –240, 1, 50 |
Operating current cooling/heating (A) | 13,8 / 10,3 |
Empfohlener Powersquerschnitt – Zuleitung Außengerät (mm²) | 3 x 2,5 |
Empfohlener Powersquerschnitt – indoor unit –Außengerät (mm²) | 4 x 1,5 |
Max. Operating current (A) | 21,4 |
Empf. Sicherungsgröße (A) | 25 |
Average product review
Important note:
Please note that by purchasing they confirm "REGULATION (EU) No. 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 üon fluorinated greenhouse gases and repealing Regulation (EC) No. 842/2006" and only a suitably certified company may carry out the installation.