Panasonic R32 Multi-Split Outdoor Unit, Inverter+.
1 - 2 connectable indoor units.
> Ready for internet control
> Energy-saving
> Heating mode down to -15 °C outdoor temperature
> Cooling mode down to -10 °C outdoor temperature
> Simple control via BMS
Multi-split inverter units offer the advantage that up to five indoor units can be connected to a single outdoor unit. In this way, the floor space occupied outdoors is reduced considerably and the energy consumption can also be reduced by up to 30%. The size of the outdoor unit model should be selected in such a way that not only the type and number of indoor unit models to be connected, but also their total output is taken into account. The tables on the following pages with the possible combinations, the technical data and the performance data should help to find the required unit combination.
Marke / Model | Panasonic / CU-2Z50TBE |
Cooling capacity min/standard/max (kW): | 1,5 / 5,0 / 5,4 |
Heating capacity Min/Standard/Max (kW): | 1,1 / 5,6 / 7,2 |
Technical data : | |
Anzahl indoor unite (Min / Max): | 1-2 |
S.E.E.R: | 8,50 |
S.C.O.P: | 4,60 |
Wirkungsgrad: | |
Energieeffizienz cooling Klasse: | A+++ |
Energieeffizienz Keizen Klasse: | A++ |
Einsatzbereich : | |
Außentemperatur Cooling mode (°C): | -10 bis +46 |
Außentemperatur Heizbetrieb (°C): | -15 bis +24 |
Elektrische Daten : | |
Power supply (V / Ph / Hz): | 240 / 1 / 50 |
Absicherung, träge (A): | 20 |
Power consumption cooling / Heizen (kW): | 1,18 / 1,21 |
Operating current Max (A): | 4,1 |
Regelung, Ventilator, Maße, Weight:e : | |
Selbstdiagnosesystem : | ja |
Ventilator (Stück): | 1 |
Luftmenge max (m³/h): | 1782 |
Sound pressure level (dB(A)): | 45 |
SchallPowerspegel (dB(A)): | 60 |
Dimensions (H x B x T) (mm): | 619 x 824 x 299 |
Weight (kg): | 39 |
Pipe-Check-Funktion: | ja |
Coolingmittelleitungen : | |
Liquid keitsleitung (Ø Zoll): | 2x 1/4" |
Sauggasleitung (Ø Zoll): | 2x 3/8" |
Coolingmittelverteiler erforderlich: | No |
Wärmeisolierung (beide Leitungen): | Ja |
Equivalente Leitungslänge Außen- / indoor unit, max (m): | ~20 |
Gesamtrohrleitungslänge Außen- / indoor unite, max (m): | 30 |
Height difference, Außengerät höher/tiefer, max (m): | 15 |
Coolingmittel: | R32 |
Coolingmittelmenge werkseitig vorgefüllt (kg / tCO e): | 1,12 / 0,756 |
Coolingmittelfüllung f. max. Leitungslänge bis (m): | 15 |
Coolingmittelnachfüllung für Mehrmeter (g/m): | 10 |
Coolingmitteleinspritzung EEV, Außengerät (steps): | 480 |
Optional und Digital | |
Systemmanagement via Internet und DMS: | Ja |
Energieerfassung- / abrechnung: | Ja |